    FFT Á¤¹Ð±Þ¼ÒÀ½°è sound Level meter
    ÆǸŰ¡°Ý °¡°Ý¹®ÀÇ
    ºê·£µå ACO
    Á¦Ç°ÄÚµå 6236 / 6238
    ÁÖ¹®¼ö·®
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦

    Sound Level Meter TYPE-6236
    Precision Sound Level Meter TYPE-6238

    On-site measurement of environmental noise is strongly expected to have high resolution and real-time analyzing function on the spot. Moreover, in the field of product development such as car parts electric appliances, etc., it is required to measure and analyze the sound of ultra-low level more accurately, corresponding to the rise of consciousness that the acoustic characteristics such as silence, tone quality, etc., should be the part of the product, which is deeply related to our human hearing sensation. The function of TYPE6236/TYPE6238 can be extended quite easily to those such as measurement of various parameters for environmental noise, only by inserting option FFT Analysis Card into the card slot. Also, this equipment is provided with newly developed ¡°0-dB function¡± for measuring ultra-low sound pressure level, symbolizing the next-generation sound level meter with extremely high resolution and reliability.

    World first!! ¡°0-dB measurement-function¡±

    0-dB measurement-function

    By employing the original DSP technology, which eliminates the self-noise of the microphone with preamplifier, the lower limit of measurement has been drastically extended to lower than 0 dB-SPL. Linearity range, extended to 100 dB in the usual state, further expands to that corresponding to the measurement range 0¢¦80dB(A) by holding the 0-dB function in ON position.

    It enables to measure ultra-low sound pressure level, so displaying its greatest power as in the quietness measurement of, or tone quality evaluation of, various silent-type IT/OA equipments, as well as in the measurement of air-conditioning noise or sound isolation in a concert hall with ambient noise below NC-20.

    ¡ØTechnology relating to ¡°0-dB measurement function¡± is the fruit of joint research work with Shizuoka University.

    Function Enhancement¡¡£­Program card (SD card)£­

    Function Enhancement¡¡£­Program card (SD card)£­

    Replacing the card with SD card (option) enables to add the specified analyzing function to TYPE6236.

    £­1/1 and 1/3-octave Real-time analysis card

    £­FTT analysis Card

    £­RSR card (Real Sound Recording Card)

    Equipped with a function of displaying NC bar graph
    with evaluated NC index

    Equipped with a function of displaying NC bar graph <br>with evaluated NC index

    In response to your great deal of needs, the function of displaying NC-bar with evaluated NC index finally equipped!!

    By inserting "1/1 and 1/3-octave Real-time Analysis Card" in TYPE6236/TYPE6238, evaluated NC index is displayed in real time, empowering the evaluation of on-site noise measurement.

    Embedded high precision microphone

    TYPE7052NRTYPE7146NR

    TYPE6236/TYPE6238 is equipped with high precision electret condenser microphone(TYPE7052NR/TYPE7146NR) which ACO is most proud of.
    The measurement frequency range covers entire audible frequencies,TYPE6236:20Hz¢¦20kHz,TYPE6238:5Hz¢¦20kHz.

    ACO Microphone is made as one with highly anti-shock capability

    TYPE7052NRTYPE7146NR

    "Microphone has a image of breakable object needing frequent replacement"

    Such an image is broken down by ACO microphone of highly anti-shock capability,developed through lengthy research and development work.
    ACO Microphones,clearing various strength tests,delivers the customers from very delicate handling of the microphone,offering the environment focused on sound measurement.

     

     

    Type
    TYPE 6236
    TYPE 6238
    Type approval number

    SLS101

    SLF101

    Name

    Sound Level Meter

    Precision Sound Level Meter

    Applicable Standards

    JIS C1509-1:2005 Class¥±
    IEC 61672-1:2002 Class ¥±

    JIS C1509-1:2005 classI
    IEC 61672-1:2002 ClassI

    Frequency Range

    20Hz¢¦20kHz
    (Conforms with
    measurement law
    20Hz¢¦8kHz)

    5Hz¢¦20kHz
    (Conforms with
    measurement law
    20Hz¢¦12.5kHz)

    Microphone Type
    £¨Sensitivity£©

    TYPE 7052NR
    (-33dB,Stand-alone -31dB)

    TYPE 7146NR
    (-29dB,Stand-alone -27dB)

    Measurement Level

    A:28¢¦130dB
    (0¢¦80dB/0-dB measurement function in ON)
    C:36¢¦130dB
    Z(FLAT):40¢¦130dB
    C peak:55¢¦141dB
    Z(FLAT)peak:60¢¦141dB

    A:28¢¦130dB
    (0¢¦80dB/0-dB measurement function in ON)
    C:37¢¦130dB
    Z(FLAT):39¢¦130dB
    C peak:55¢¦141dB
    Z(FLAT)peak:60¢¦141dB

    Self-noise level

    The lower limit of the measurement range in dB lies 6dB higher than self-noise level.

    The lower limit of the measurement range in dB lies 8dB higher than self-noise level.

    Level Range Control

    10dB 6step
    20¢¦80dB¡¢20¢¦90dB¡¢20¢¦100dB
    20¢¦110dB¡¢30¢¦120dB¡¢40¢¦130dB
    (0¢¦80dB£¯0-dB measurement function in ON)

    Linearity Range

    100dB

    Time weighting

    Fast¡¢Slow¡¢Impulse

    Frequency weighting

    A¡¢C¡¢Z(FLAT)

    Measurement items

    Sound pressure level(L p )
    A-weighted sound pressure level
    C-weighted sound pressure level(L A /L C )
    Equivalent continuous A-weighted sound pressure level(L Aeq )
    Sound Exposure level(L AE )
    Maximum sound pressure level(L Amax )
    Minimum sound pressure level(L Amin )
    Percentile sound pressure level(5 freely selectable values¡¢L AN )
    Peak Sound Pressure level(L peak )
    C- weighted Peak Sound Pressure level(L Cpeak )
    Power average of maximum sound pressure level in a given interval(L Atm5 )
    Impulse Sound pressure level(L AI )
    Impulse equivalent continuous sound pressure level(L AIeq )

    Measurement time

    1s/3s/5s/10s/1min/5min/10min/15min/30min/1h/8h/12h/24h
    Manual(Max. 199h59m59s)

    Sampling Time

    20.8¥ìs(L eq ¡¢L max ¡¢L min )¡¢100ms(L N )

    Data clear Function

    Pause, and a function that deletes preceding 3 or 5 sec. dat
    Memory start£»Selectable Auto or Manual

    Timer function

    A marker can be set to start and stop the measurement at any specified moments.

    Display

    Liquid crystal and Backlight(128¡¿64 points)

    Digital display

    Display range:4digit display
    Display cycle£ºdisplay Period: 1s

    Bar display

    Display Period:0.1s

    Warning

    Over£»+3dB from upper limited scale
    Under£»£­0.6dB from lower limited scale

    Battery display

    Battery¡¡5 ste£ðs display

    Date

    year/month/day/hour£ºminute£ºsecond

    T Pause

    ormal pause function, as well as the function of canceling the data before pausing the measurement, are available.

    Calibration signal

    Electric calibration with internal oscillator (1kHzsine wave)

    AC Output

    ¥õ2.5Jack
    Output£º1Vrms(FS)
    Output impedance£º600¥Ø
    Load impedance£ºmore than 10k¥Ø

    DC Output

    ¥õ2.5Jack
    Output£º2.5V(FS)
    0.25V/10dB Output impedance£º50¥Ø
    Load impedance£ºmore than10k¥Ø

    RMS detection circuit

    True RMS detection circuit£¨computing type£©

    Processing

    Digital

    Data Storage Functions

    Sound pressure level or Processed values stored in built-in Memory or Memory card
    Manual Storage£ºSound level, Calculation value, Memory time,Store the Sampling to Built-in memory or on Memory card,
    Auto Storage£ºSampling interval 100ms, 200ms, sound level,Leq etc. Processing Card £ºStorage of calculation results

    I/O

    Direct output to printer, control and output data to computer Digital output of real-time noise waveform with USB interface

    Comparator Output

    Comparator Function with threshold level

    Battery Type

    Four 1.5V Alkaline cells IEC type LR6, Optional AC adapter

    Battery life

    Alkaline dry cell ; Approx.9hours when Switch on a back light ;Approx.1/3

    Operating temperature

    Temperature£º-10¢¦50¡É
    Humidity£º30%¢¦90%RH(no condensation)

    Size

    86(W) x 285(H) x 46(D)

    Weight

    Less than APPROX£¨450g(including Batteries)

    * °è»ê¼­ ¹ßÇà ¿äû½Ã ¹ßÇà °¡´ÉÇÕ´Ï´Ù . (Ä«µå ±¸ÀԽà Á¦¿Ü ) * ¹«´Ü º¹À縦 ±ÝÇÕ´Ï´Ù .
    »óÇ°Á¤º¸°í½Ã
    Á¦Ç°¸í FFT Á¤¹Ð±Þ¼ÒÀ½°è sound Level meter
    ÆǸŰ¡°Ý °¡°Ý¹®ÀÇ
    ºê·£µå ACO
    °ü·Ã»óÇ°
        
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
    ¾ÆÁ÷ ÀÛ¼ºµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
     
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥
    ÀÛ¼ºµÈ »óÇ°¹®ÀÇ°¡ ¾ø½À´Ï´Ù.
      »óÇ°¹®ÀÇÇϱâ
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹ÝÇ°±³È¯
    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
    - ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
    - ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
    - ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    !! ÁÖÀÇ»çÇ×
    ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
    ¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
    ¹è¼Û¾È³»
    °áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
    ±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ¿»·Î¿ìĸÅù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
    ¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà ¹«·á¹è¼ÛÀÔ´Ï´Ù.
    (Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)
    °áÁ¦¾È³»
    °áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
    Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
    »óÈ£ : ¿¡À̺ñÅ¥     ÁÖ¼Ò : ÀÎõ °è¾ç±¸ ÀÛÀüµ¿ 859-11     ´ëÇ¥ÀÚ : ÇãÁ¾¼ø     »ç¾÷ÀÚµî·Ï¹øÈ£ : 573-06-02527 (Á¤º¸È®ÀÎ)
    Åë½ÅÆǸž÷½Å°í : Á¦2022-ÀÎõ°è¾ç-1264È£     ºÎ°¡Åë½Å»ç¾÷ÀÚ¹øÈ£ :      °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : ±èÈñÁ¤     °³ÀÎÁ¤º¸º¸È£±â°£ : ȸ¿øÅ»Åð½Ã
    È£½ºÆü­ºñ½ºÁ¦°ø¾÷ü : µðÁöÀ¥