¿À´Ã º» »óÇ° (0)
    no
    show
    °ßÀû¹®ÀÇ
    ½Ç½Ã°£°ßÀû
    ±â¼úÀÚ·á½Ç
    °øÁö»çÇ×
    Áú¹®°ú ´äº¯
    °í°´¼¾ÅÍ
    T.032-579-1191
    ¿ù - ±Ý : 09:00 ~ 18:00
    Á¡½É : 12:00 ~ 13:00
    Åä, ÀÏ, °øÈÞÀÏ ÈÞ¹«
    °í°´¼¾ÅÍ ¿¬°áÀÌ Àß µÇÁö¾ÊÀ»½Ã
    Q&A °Ô½ÃÆÇÀ» ÀÌ¿ëÇØÁÖ¼¼¿ä.

    Vivo Micro À̹Ì¡ ½Ã½ºÅÛ ,OASIS Micro
    ÆǸŰ¡°Ý °¡°Ý¹®ÀÇ
    ºê·£µå Mightex
    Á¦Á¶»ç Usa
    Á¦Ç°ÄÚµå OASIS Micro
    ÁÖ¹®¼ö·®
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦

    In Vivo Micro imaging system with high resolution objectives

    »óÇ° »ó¼¼¼³¸í

    OASIS Micro features infinity-corrected optics and accepts 'standard' microscope objective lenses. This system will provide a FoV and output intensity (from a Polygon or a wide-field illuminator) that are similar to when using a commercial microscope (e.g. Nikon, Leica, Olympus or Zeiss). Therefore, OASIS Micro is recommended for applications that require high resolution similar to that of a typical commercial microscope, but at the same time also calls for excellent reconfigurability/flexibility for live animal investigation.

    Translates and Rotates for Live Animal Research
    Simultaneously Image & Deliver Wide-field and/or Pattern Illumination
    Macro or Microscopic Optical Assembly
    Modular Platform Tailors to any Experimental Application
    Excellent System for:
    In Vivo Optogenetics
    Photostimulation
    Photoactivation

     

    OASIS_system_Fig1a.jpg

    Customer Reference:

    OASIS modular system for live animal optogenetic stimulation.

    Researchers at NYU use Mightex's OASIS to study spatio-temporal codes in the olfactory bulb of awake and behaving mice.

     

    http://www.mightexsystems.com/images/Image/Theo_cus_ref_chart.png

    White Paper:

    Patterned Illumination Systems for Optogenetics

     

     

    Mightex's Optical Activation, Stimulation and Imaging System (OASIS) is designed specifically to meet the growing demand to conduct experiments on live animals, when system flexibility is a primary consideration and a large Field of View (FoV) is usually required. In Optogenetics, for example, in vivo patterned illumination on rodents, monkeys and other animals is the next step towards the ultimate goal of being able to record and control the activity of each neuron in the brain of behaving animals at a single cell and ms resolution. To achieve patterned illumination for in vivo applications, the OASIS features Mightex¡¯s market-leadingPolygon400 patterned Illuminator to deliver light to a specified area of the specimen while leaving neighboring areas untouched.

    Whereas traditional microscopes are a fixed system with limited flexibility, OASIS is designed to provide excellent reconfigurability/flexibility and can be configured to work around a fixed specimen such as a sedated live animal. A heavy-duty precision XYZ stage is mounted on the support structure and the OASIS optical assembly is in turn mounted on the XYZ stage. The XYZ stage controls the lateral motion as well as focus of the system. A pan/tilt mechanism add-on is also available to orient the OASIS relative to the live animal. Motorized versions of both the XYZ stage and tilt mechanism are available.

    OASIS Schematic

    2bcdb379ca58b32e2aeb6ff6d56e092f_1450153

    OASIS Illumination Overview

    OASIS features several illumination options that customers can take advantage of. One of the most important options is the option to integrate Mightex¡¯s market leading Polygon400 patterned illuminator to perform in vivo & in vitro patterned illumination options. A wide field illumination option is available where users can select any number of wavelengths between (240nm-940nm) and couple it into OASIS.

    In addition to selecting wide-field or patterned illumination options, OASIS is configurable and flexible to incorporate multiple patterned illumination or wide illumination devices to provide maximum versatility possible. To identify the illumination set-up that is ideal for your research our support team will be glad to walk you through the choices.


    OASIS Illumination Options

    OASIS with Patterned Illuminator

    Schematic Shows the Single
    Patterned Illuminator Option
    Polygon400
    List of OASIS Illumination Options
    1. Single Polygon400 Patterned Illuminator
    2. Multi or Single Wavelength Wide-field Illumination setup
    3. Polygon400 + Wide-field Setup
    4. Dual Polygon400 Setup

     


    Polygon400 Specifications with OASIS

    A popular choice for customers is to use Mightex¡¯s market leading Polygon400 with OASIS. Either a Polygon400 with built-in LEDs (E-Series) or with a lightguide input to be used with external LED Sources (G-Series) can be used. Polygon E-Series is suitable for customers requiring only 1-3 wavelengths, while Polygon G-Series is advantageous when customers want to work with their existing light sources or want to use super-high power illuminations sources like Mightex¡¯s Type-H LEDs.

    For more information comparing the different Polygon series options please take a look at our Polygon400 overview page here.


    Polygon400 Projection Area with OASIS Micro

    Projection Area Common Microscopes
    Leica Nikon Olympus Zeiss
    Height (mm) 8.7 8.7 7.8 7.2
    Width (mm)
    15.5 15.5 13.9 12.7
    Diagonal (mm) 17.7 17.7 16.0 14.6
    Pixel size (¥ìm)
    18.0 18.0 16.2 14.8

    To calculate illumination area and pixel resolution at the specimen, simply divide the above numbers by the magnification of the objective. For example, under a 10x objective on an Olympus microscope, the illumination area will be 0.78mm x 1.39mm with a pixel resolution of 1.62¥ìm.

    Polygon400 Output Power with OASIS Micro

    Wavelength (nm) Output Power (mW)
    400 14.0
    470 15.0
    530 4.5
    590 3.0
    617 14.0
    630 14.0
    656 14.0

     

    OASIS Compatible Cameras

    OASIS Standard configuration features a C-Mount camera mounting which allows OASIS to be used in conjunction with any C-Mount camera. For customers without a camera to use with OASIS Mightex also offers a portfolio of robust CCD Microscopy Cameras that are cost effective imaging solutions with excellent performance. More information about Mightex cameras can be found here.

    OASIS Camera Options


    OASIS Camera Compatibility
    Compatible with all C-Mount Cameras

    For Mightex Microscopy Cameras Please Click Here

    Schematic Shows a Mightex CCD camera mounted on OASIS Micro.

     

    OASIS Compatible Objectives

    If using OASIS Micro most major commercial microscope objectives will be compatible with the system. Just let our support team know which objective you plan to use and they will make sure to select an optical assembly configuration for the vendor objective. Mightex is also able to provide objectives with the OASIS as an add on as well. Let us know your key requirements and we will be glad to make a recommendation.

    If using OASIS Macro there are three objectives option that the user can choose between This includes a 4X, 2.35X and 1.9X Macro objectives.


    OASIS Optical Assembly Options

     

    OASIS LED Controller Options


    List of OASIS Controller Options
    1. BLS-1000/3000/13000 Analog & Manual Controllers
    2. BLS-SA/PL Software & TTL Controllers
    3. (BLS-PAD-000) + (#2)
    4. (BLS Digital I/O Box) + (#1)
    Schematic Shows a Mightex BLS-SA/PL Controller

     

     

    OASIS Compatible BioLED Controller Summary Chart 

      Manual Software Analog TTL
    BLS-SAxx-US
    BLS-PLxx-US
    BLS-1000-2
    BLS-3000-2
    BLS-13000-1
    BLS-SA/PLxx-US +
    BLS-PAD-000
    BLS-1000/3000/13000 + BLS-IO04-US


    For more information about each Mightex BioLED controller please follow the links in the table above.

     

     

    For more technical details and specifications, please check

    * °è»ê¼­ ¹ßÇà ¿äû½Ã ¹ßÇà °¡´ÉÇÕ´Ï´Ù . (Ä«µå ±¸ÀԽà Á¦¿Ü ) * ¹«´Ü º¹À縦 ±ÝÇÕ´Ï´Ù .
    »óÇ°Á¤º¸°í½Ã
    Á¦Ç°¸í Vivo Micro À̹Ì¡ ½Ã½ºÅÛ ,OASIS Micro
    ÆǸŰ¡°Ý °¡°Ý¹®ÀÇ
    ºê·£µå Mightex
    Á¦Á¶»ç Usa
    °ü·Ã»óÇ°
        
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
    ¾ÆÁ÷ ÀÛ¼ºµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
     
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥
    ÀÛ¼ºµÈ »óÇ°¹®ÀÇ°¡ ¾ø½À´Ï´Ù.
      »óÇ°¹®ÀÇÇϱâ
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹ÝÇ°±³È¯
    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
    - ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
    - ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
    - ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    !! ÁÖÀÇ»çÇ×
    ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
    ¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
    ¹è¼Û¾È³»
    °áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
    ±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ¿»·Î¿ìĸÅù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
    ¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà ¹«·á¹è¼ÛÀÔ´Ï´Ù.
    (Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)
    °áÁ¦¾È³»
    °áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
    Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
    »óÈ£ : ¿¡À̺ñÅ¥     ÁÖ¼Ò : ÀÎõ °è¾ç±¸ ÀÛÀüµ¿ 859-11     ´ëÇ¥ÀÚ : ÇãÁ¾¼ø     »ç¾÷ÀÚµî·Ï¹øÈ£ : 573-06-02527 (Á¤º¸È®ÀÎ)
    Åë½ÅÆǸž÷½Å°í : Á¦2022-ÀÎõ°è¾ç-1264È£     ºÎ°¡Åë½Å»ç¾÷ÀÚ¹øÈ£ :      °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : ±èÈñÁ¤     °³ÀÎÁ¤º¸º¸È£±â°£ : ȸ¿øÅ»Åð½Ã
    È£½ºÆü­ºñ½ºÁ¦°ø¾÷ü : µðÁöÀ¥