    Á¦Ç°Æ¯Â¡

    Universal laboratory hot plate with revolutionary technology and new functions:
    - Integrated temperature control
    - Incl. PT 1000 temperature sensor (PT 1000.60)
    - Exact temperature setting via digital display, even when switched off
    - Set safety temperature limit displayed digitally
    - Hot Top indicator >> hot surface warning to prevent burns!
    - Digital error code display
    - With adjustable safety circuit of heating plate temperature (50 - 360 ¡ÆC)
    - Hot plate, suitable for unsupervised operation
    - Bushing according to DIN 12878 for connecting a contact thermometer, e.g. TC 3 enables precise temperature control
    - High level of safety thanks to improved heat control technology
    - Enclosed assembly (IP 42) guarantees long service life
    - Highly polished aluminium heating plate for optimum heat transfer

    Á¦Ç°»ç¾ç

    - Number of heating points [-] 1
    - Heat output [W] 600
    - Heating temperature range [¡ÆC] 50 - 310
    - Heat control [-] LED
    - Heat control accuracy [¡¾K] 1
    - Connection for ext. temperature sensor [-] DIN 12 878
    - Control accuracy with sensor [¡¾K] 1
    - Heating rate (1 l H2O in H15) [K/min] 6.5
    - Set-up plate material [-] Aluminium alloy
    - Set-up plate dimensions [mm] ¨ª 135
    - Adjustable safety circuit min. [¡ÆC] 50
    - Adjustable safety circuit max. [¡ÆC] 360
    - Dimensions (W x H x D) [mm] 165 x 85 x 275
    - Weight [kg] 2.5
    - Permissible ambient temperature [¡ÆC] 5 - 40
    - Permissible relative moisture [%] 80
    - Protection class according to DIN EN 60529 [-] IP 42
    - Voltage [V] 220 - 230 / 115 / 100
    - Frequency [Hz] 50/60
    - Power input [W] 640

    * °è»ê¼­ ¹ßÇà ¿äû½Ã ¹ßÇà °¡´ÉÇÕ´Ï´Ù . (Ä«µå ±¸ÀԽà Á¦¿Ü ) * ¹«´Ü º¹À縦 ±ÝÇÕ´Ï´Ù .
    »óÇ°Á¤º¸°í½Ã
    Á¦Ç°¸í Àڷ±³¹Ý±â, ¸¶±×³×ƽ±³¹Ý±â ,HST-digital-[5002600]
    ÆǸŰ¡°Ý 890,000¿ø
    ºê·£µå IKA
    Á¦Á¶»ç IKA
    °ü·Ã»óÇ°
        
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
    ¾ÆÁ÷ ÀÛ¼ºµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
     
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥
    ÀÛ¼ºµÈ »óÇ°¹®ÀÇ°¡ ¾ø½À´Ï´Ù.
      »óÇ°¹®ÀÇÇϱâ
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹ÝÇ°±³È¯
    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
    - ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
    - ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
    - ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    !! ÁÖÀÇ»çÇ×
    ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
    ¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
    ¹è¼Û¾È³»
    °áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
    ±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ¿»·Î¿ìĸÅù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
    ¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà ¹«·á¹è¼ÛÀÔ´Ï´Ù.
    (Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)
    °áÁ¦¾È³»
    °áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
    Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
    »óÈ£ : ¿¡À̺ñÅ¥     ÁÖ¼Ò : ÀÎõ °è¾ç±¸ ÀÛÀüµ¿ 859-11     ´ëÇ¥ÀÚ : ÇãÁ¾¼ø     »ç¾÷ÀÚµî·Ï¹øÈ£ : 573-06-02527 (Á¤º¸È®ÀÎ)
    Åë½ÅÆǸž÷½Å°í : Á¦2022-ÀÎõ°è¾ç-1264È£     ºÎ°¡Åë½Å»ç¾÷ÀÚ¹øÈ£ :      °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : ±èÈñÁ¤     °³ÀÎÁ¤º¸º¸È£±â°£ : ȸ¿øÅ»Åð½Ã
    È£½ºÆü­ºñ½ºÁ¦°ø¾÷ü : µðÁöÀ¥