¿À´Ã º» »óÇ° (0)
    no
    show
    °ßÀû¹®ÀÇ
    ½Ç½Ã°£°ßÀû
    ±â¼úÀÚ·á½Ç
    °øÁö»çÇ×
    Áú¹®°ú ´äº¯
    °í°´¼¾ÅÍ
    T.032-579-1191
    ¿ù - ±Ý : 09:00 ~ 18:00
    Á¡½É : 12:00 ~ 13:00
    Åä, ÀÏ, °øÈÞÀÏ ÈÞ¹«
    °í°´¼¾ÅÍ ¿¬°áÀÌ Àß µÇÁö¾ÊÀ»½Ã
    Q&A °Ô½ÃÆÇÀ» ÀÌ¿ëÇØÁÖ¼¼¿ä.

    ±¤¹° ºÐ±¤ TerraSpec 4 Hi-Res Mineral Spectrometer
    ÆǸŰ¡°Ý °¡°Ý¹®ÀÇ
    ºê·£µå asdi
    Á¦Á¶»ç usa
    Á¦Ç°ÄÚµå TerraSpec 4
    ÁÖ¹®¼ö·®
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    Recognized as the de facto technology for mineralogical analysis, the rugged portable TerraSpec mineral spectrometers are trusted by top geologists for performing fast, precise geologic exploration. Now the upgraded TerraSpec 4 Hi-Res mineral analyzer brings new levels of efficacy to mineral exploration technology. This state-of-the-art mineral spectrometer offers enhanced performance in the SWIR 1 and 2 regions and a 6 nm resolution to help you determine the viability of mineral exploration targets faster and more precisely than ever before. These enhancements provide you with the ability to capture accurate spectral data more quickly, especially for samples with darker mineral features.

    • Enhanced optical configuration provides more precise spectral results for superior spectrum clarity and definition.
    • 2x the performance in the SWIR 1/SWIR 2 regions translates into better alteration mineral analysis.   
    • Improved portability features, including a new backpack and standard 802.11g Wi-Fi, help you move through exploration field sites more freely.
    • Standard ruggedized steel covered fiber optic cable ensures consistent spectral quality.
    • No need for sample prep, which means fast field scans.

     

    For mining exploration geologists, these improvements translate into faster data capture at exploration targets and drilling sites. The improved data quality provided by the TerraSpec 4 Hi-Res mineral spectrometer also allows for accurate assessment of low-concentration and low-reflectance minerals, like iron-containing minerals such as serpentines and chlorites, which were previously difficult to measure.

    The TerraSpec 4 Hi-Res mineral analyzer has been optimized for a range of mineral exploration applications, including deposit mapping.

    -SPECS-

    Wavelength range 350-2500 nm

    Resolution 3 nm @ 700 nm and 6 nm @ 1400/2100 nm

    Scanning time 100 milliseconds

    Signal-to-noise ratio VNIR: 9,000:1 @ 700 nm

    SWIR 1: 9,000:1 @ 1400 nm

    SWIR 2: 4,000:1 @ 2100 nm

    Stray light VNIR: 5000:1 (0.02%)

    NIR: 10,000:1 (0.01%)

    Wavelength reproducibility 0.1 nm

    Wavelength accuracy 0.5 nm

    Channels 2151

    VNIR detector (350-1000 nm) 512 element silicon array

    SWIR 1 & 2 detectors (1001-1800 nm) & (1801-2500 nm) Graded Index InGaAs Photodiode, TE Cooled

    Certification and Approvals CE certified: EN61010-1:2001 2nd Edition

    EU Directive: 2006/95/EC, 2004/108/EC

    NIST traceable calibration

    WEEE Compliance

    Communications Wired: 10/100 Base T Ethernet port with Ethernet cross-over cable

    Wireless: 802.11g wireless card

    Dimensions (H x W x D) 12.7 x 36.8 x 29.2 cm (5 x 14.5 x 11.5 in)

    Weight 5.44 kg (12 lbs)

    Battery weight 1.2 kg (2.7 lbs)

    Battery run time Approximately 6 hours (without lamps or accessories)

    Operating temperature 0 to 40¡Æ C (32 to 104¡Æ F)

    Storage temperature -15 to 45¡Æ C (5 to 113¡Æ F)

    Input power AC/DC switching power supply and a sealed lead-acid gel cell battery

    AC input 90-240 VAC, 50/60 Hz

    DC input 12 VDC, 60 W

    Auxiliary port power Output, +12 VDC, 27 Watt (max)

    Software RS3¢â spectral acquisition software, Compatibility with The Spectral Geologist and SpecMin, Seamless interface with ENVI?, ASD ViewSpec¢â Pro for post processing, optional Indico? Pro

    Portability Rugged instrument transportation case; optional customized backpack with soft-sided travel bag

    Warranty One year full warranty including expert customer support

    Computer Windows? 7 64-bit laptop (instrument controller)

    * °è»ê¼­ ¹ßÇà ¿äû½Ã ¹ßÇà °¡´ÉÇÕ´Ï´Ù . (Ä«µå ±¸ÀԽà Á¦¿Ü ) * ¹«´Ü º¹À縦 ±ÝÇÕ´Ï´Ù .
    »óÇ°Á¤º¸°í½Ã
    Á¦Ç°¸í ±¤¹° ºÐ±¤ TerraSpec 4 Hi-Res Mineral Spectrometer
    ÆǸŰ¡°Ý °¡°Ý¹®ÀÇ
    ºê·£µå asdi
    Á¦Á¶»ç usa
    °ü·Ã»óÇ°
        
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ º°Á¡ ³¯Â¥
    ¾ÆÁ÷ ÀÛ¼ºµÈ »óÇ°ÆòÀÌ ¾ø½À´Ï´Ù.
     
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹øÈ£ Á¦¸ñ À̸§ ³¯Â¥
    ÀÛ¼ºµÈ »óÇ°¹®ÀÇ°¡ ¾ø½À´Ï´Ù.
      »óÇ°¹®ÀÇÇϱâ
    »ó¼¼¼³¸í »óÇ°Èıâ(0) »óÇ°¹®ÀÇ(0) ±³È¯ ¹× ¹ÝÇ°/¹è¼Û/°áÁ¦
    ¹ÝÇ°±³È¯
    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì
    - ±¸ÀÔÈÄ 7ÀÏ À̳»¿¡ µ¿ÀÏÁ¦Ç°À¸·Î ±³È¯ °¡´ÉÇÏ¸ç ¿î¼Ûºñ´Â ÆǸÅÀÚ ºÎ´ãÀÔ´Ï´Ù.
    - ´Ù¸¥ Á¦Ç°À¸·Î ±³È¯, ¶Ç´Â ÀÌ»óÀÌ ¾ø´Â Á¦Ç°°ú ÇÔ²² ±³È¯À» ¿øÇÏ½Ç °æ¿ì ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    ±¸ÀÔÁ¦Ç°ÀÇ ÀÌ»óÀÌ ÀÖÀ» °æ¿ì (»ö»ó,»çÀÌÁî,´Ù¸¥»óÇ°±³È¯)
    - ±¸ÀÔÈÄ 7ÀÏÀ̳» ±³È¯ °¡´ÉÇÏ¸ç ±¸¸ÅÀÚ²²¼­ ¿î¼Ûºñ¸¦ ºÎ´ãÇÕ´Ï´Ù.

    !! ÁÖÀÇ»çÇ×
    ºñ´ÒÆ÷Àå ¹× TagÀÇ Æó±â ¶Ç´Â ÈÑ¼Õ µîÀ¸·Î »óÇ° °¡Ä¡°¡ ¸ê½ÇµÈ °æ¿ì¿¡´Â Á¦ÇÑ.
    ¹ÝÇ°½Ã¿¡ ÇØ´ç »çÀºÇ°ÀÌ ÀÖÀ» °æ¿ì °°ÀÌ º¸³»ÁÖ¼Å¾ß ÇÕ´Ï´Ù.
    ¹è¼Û¾È³»
    °áÁ¦ÈÄ 3~7ÀÏ À̳»¿¡ »óÇ°À» ¹Þ¾Æ º¸½Ç ¼ö ÀÖ½À´Ï´Ù.
    ±¹³» ÃÖ´ëÀÇ ¹°·ù»ç ¿»·Î¿ìĸÅù踦 ÅëÇÏ¿© ½Å¼ÓÇÏ°í ¾ÈÀüÇÏ°Ô ¹è¼ÛµË´Ï´Ù.
    ¸ðµç Á¦Ç°Àº ÂøºÒ ¹ß¼ÛµË´Ï´Ù. ´Ü 30¸¸¿ø ÀÌ»ó ±¸ÀԽà ¹«·á¹è¼ÛÀÔ´Ï´Ù.
    (Á¦ÁÖµµ¸¦ Æ÷ÇÔÇÑ µµ¼­,»ê°£Áö¿ªÀº Ç×°ø·á ¶Ç´Â µµ¼±·á°¡ Ãß°¡µË´Ï´Ù.)
    °áÁ¦¾È³»
    °áÁ¦¹æ¹ýÀº ½Å¿ëÄ«µå, ±¹¹Î/BC(ISP), ¹«ÅëÀåÀÔ±Ý, Àû¸³±ÝÀÌ ÀÖ½À´Ï´Ù.
    Á¤»óÀûÀÌÁö ¸øÇÑ °áÁ¦·Î ÀÎÇÑ ÁÖ¹®À¸·Î ÆÇ´ÜµÉ ¶§´Â ÀÓÀÇ·Î ¹è¼ÛÀÌ º¸·ùµÇ°Å³ª,ÁÖ¹®ÀÌ Ãë¼ÒµÉ ¼ö ÀÖ½À´Ï´Ù.
    »óÈ£ : ¿¡À̺ñÅ¥     ÁÖ¼Ò : ÀÎõ °è¾ç±¸ ÀÛÀüµ¿ 859-11     ´ëÇ¥ÀÚ : ÇãÁ¾¼ø     »ç¾÷ÀÚµî·Ï¹øÈ£ : 573-06-02527 (Á¤º¸È®ÀÎ)
    Åë½ÅÆǸž÷½Å°í : Á¦2022-ÀÎõ°è¾ç-1264È£     ºÎ°¡Åë½Å»ç¾÷ÀÚ¹øÈ£ :      °³ÀÎÁ¤º¸°ü¸®Ã¥ÀÓÀÚ : ±èÈñÁ¤     °³ÀÎÁ¤º¸º¸È£±â°£ : ȸ¿øÅ»Åð½Ã
    È£½ºÆü­ºñ½ºÁ¦°ø¾÷ü : µðÁöÀ¥